NBC Air Filtration Equipment

Blast Protection
Equipment

Isolation Rooms Military Vehicles 

Overpressure Relief Valve
Ultra-low pressure purge valve


The ASR-50-OP wall mount version

$145.00 (USD)
ASR-50-OP-W Wall Mount
Click on the star to order

 


The ASR-50-OP ceiling mount version

$145.00 (USD)
Click on the star to order

ASR-50-OP-C Ceiling Mount

 

Overpressure relief valve technical manual
Click on the image above
to download the installation and operation manual for the Overpressure Relief Valve (PDF)

 

This overpressure relief valve is critical to creating an overpressure in the protected space by adding the proper, metered resistance to the outgoing airflow. The valve is normally closed and will not open unless the air pressure inside the shelter is slightly greater than the outside air pressure.

This gives you true ventilation - air in through the Safe Cell and out through this valve preventing the buildup of carbon dioxide exhaled by the occupants. Carbon dioxide poisoning will incapacitate and kill the occupants of an enclosed space without ventilation long before oxygen deprivation.

Please specify at time of ordering whether or not you are mounting this valve directly on the wall or ceiling - or if you are going mount it to the blast valve. We will configure your overpressure relief valve so it either has a mounting flange for the wall or ceiling or a slip-fit connection for the blast valve.

A good rule of thumb is that if you are underground, you need blast valves and if you are above ground, you do not - unless you have a hardened structure above ground. There is not much need for blast valves unless you have a hardened, blast resistant structure.

Any protected space will benefit from this valve, especially if it is well sealed, then this overpressure relief valve is a necessity - if you want true ventilation.

 


You are on this page:
www.AmericanSafeRoom.com/
Safe-Cell-overpressure-valve.htm

American Safe Room Websites:
AmericanSafeRoom.com
AmericanBombShelter.com

AmericanIsolationRoom.com
BuyRelyOnHere.com

Contact Information:
American Safe Room, Inc.
868 Murdock Drive / PO Box 255
Oakland, OR 97462

Telephone: 541-459-1806
FAX: 503-212-6695
E-mail:
info@mailasr.com
sales@mailasr.com

 

 

 

Products

Filter/ventilation systems

AC only filter

Through the wall kit

Register duct kit

Overpressure valve

Emergency hand pump

Automatic ventilation kit

Replacement filters

Automotive vent kit

Safe room doors

 
Installations

Home and apartment

Underground bomb/fallout shelter

Hospital isolation room

Military and civilian vehicles

 

Information

It's that simple ...

Safe Cell Features

OEM Services

 
Reference

Home page

Contact page

DuPont™ RelyOn™ MDC
Surface Disinfectant